shipballastwater2

As of September 8, 2016 the Ballast Water Convention officially was ratified by the IMO, crossing the necessary threshold of 35% of world tonnage signed on courtesy of the ratification by Finland. Subsequently, the United States Coast Guard was moving rapidly to confirm type approval of BWMS systems, to date confirming the approval of three systems from Alfa Laval, Oceansaver and Optimarin.

In this edition we delve into the Ballast Water Convention, United States Coast Guard Regulations, and what this all means as far as onboard operations.
The ballast water is the water that is taken onboard a vessel in one port and transits with the vessel to another port, where it is subsequently discharged. In the past this practice has transported a diversity of organisms into environments where they have no natural predator, enabling the organisms to flourish and create potential destruction to the local environment.
For many years anti-fouling paint was used in conjunction with ballast water management plans to deter organisms from attaching to a vessel’s hull or the inside of a ballast tank for transport. The problem, however, was that many of these paints turned out to be just as harmful to the environment as the organisms themselves being transported on the ship’s hull, while ballast water management plans did not completely prevent the spread of invasive species.
In regards to ballast water technology, there are a host of system types, most which fall under two general umbrellas: physical solid-liquid separation and disinfection. From these broad generalizations, the differing types of ballast water systems branch off dramatically in type and methodology used to kill organisms.
There are even specific guidelines for vessels that will discharge its ballast water to an off-vessel treatment facility. Procedures for the approval of Ballast water Management systems falls under MEPC.174 (58) and they are detailed regarding the type of results should be shown from a system seeking approval. What is not shown is which testing methods are to be used, a serious problem facing the industry.
Overcoming Implementation Problems
When dealing with an international convention such as this, the Flag State must develop the rules specific for that registry for the ship owners to follow. However Port State Control interprets the rules as well and may have a different interpretation than the Flag or the Recognized Organization. This can lead to years of confusion until all involved parties become more familiar with the application of the convention.
ThThe IMO has specified testing standards under MEPC.173(58). These guidelines specify the maximum amount of viable organisms allowed in treated ballast water; as well as the format for recording the sampling (but not the actual operation itself). There are even instructions on how to obtain samples, and how sampling points are to be installed on board a vessel. However, the IMO states “At present time, there are no specific sampling or analysis protocols that can be recommended for Administrations to use.”
The circular goes on to state “To aid this process, Administrations are requested to supply information on any scientifically validated sampling and analysis techniques to the organization, as soon as possible.”
So that leaves the Administration, Recognized Organization, and the Port State Control Officer with the burden of figuring out how to actually sample the ballast water in an agreed method, with results coming in a range from a few hours to a few weeks, at which point a vessel is usually long gone.
However, without testing how can PSC verify that the Ballast Treatment System is actually working and in compliance?
Normally the answer to that question is the use of a log book. However, unlike the Garbage Record Book or Oil Record Book as specified under MARPOL, the Ballast Water Convention does not have a specific form for a log book, thus leaving Flag and Owner alike in the dark as to what the independent and sometimes conflicting MOU regimes, with their various PSC’s, are going to expect in the way of record keeping. Most of the reviewed Ballast Treatment Systems log information such as flow rate, length of time run, and other such information. There is no guarantee though that this is what will actually be required to be kept on board. And if the system data is to suffice, how long must the system maintain the record?
This all must be determined before an amendment to STCW can be made in include the training of key shipboard personnel in this environmentally critical system. Manufacturers are developing instructional data for individual units. Most manufacturers only intend to visit the vessel upon installation to train the crew on board, leaving it to those crews to train their reliefs.
Although this is industry standard, this tradition of training via relief may not be the best practice for critical systems such as a Ballast Water Treatment System.
The Ballast Water Convention, although seriously needed, is a prime example of a Convention being pushed on industry without a well thought out plan on implementation. One could argue that without the plan, the technology never would have developed. However, a thorough analysis by the IMO would have shown that the technology may not be ready for the intended use. The industry as a whole needs to be more involved in the Codes and Conventions proposed by the IMO; involvement not to inhibit progress, but to make it manageable and allow the industry proper time to develop the technology and practices needed.

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s